• Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
  • Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
  • Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
  • Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
  • Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
  • Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump

Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump

Certification: CE, RoHS, UL
Application: Heater
Principle: Mixing Heat Exchanger
Style: Drum Type
Material: Copper
Liquid Flow Rate: 4m3/H
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Maximum Working Pressure
5.0MPa
Voltage
220V/380V
Heating Capacity
11.8kw
Warranty
24month
Medium ( Refrigerant Gas )
R22, R407c, R134A, R404A, R410A, R600A
Cooling Capacity
21kw
Transport Package
Packed by Seaworthy Export Cartons and Pallet
Specification
GAHE-01
Trademark
ECOICE
Origin
China
HS Code
8419
Production Capacity
500000PCS Per Year

Product Description

GBHE-01 accumulator excluded heat exchanger use for heat pump

 

      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump

      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump


      Work Condition:

      1)Refrigerant side (Between the tube and shell):R22,R134a,R407c,R410a            
      2)Water side (in the tube):Domestic water,Nature water,antifreeze (glycol water)

      3)This structure  A used as condenser,For heat mode. 

       

      Material:
      1)Heat transfer Tube: copper finned tube,nickel-copper finnedtube,double-wall copper tube.

      2)shell: High quality steel (4mm thickness).

       

      Features:
      • Self-patented technology. 
      • Optimized heat-transferring effect.
        structure, the medium flows more smoothly and enhance 
      • Heat-transferring rate increase 20% compared with traditional ones.

       

      High Effciency of Heat Exchange:
      1)Use efficiency finned copper  tube, heat exchange area is 3.6 times than the Smooth Tube.,it is one  important cause of high efficiency.
      2)Inside the tube is screw thread,inside and outside of tubes induce turbulence flow of freon and water,it's another cause of high efficiency.
      3)The compact helix structure of the coil ensures sufficient heat exchange between the gas and water.

       

      Safety:
      1)Whole tube inside shell has no internal joint,that means no welding bug.
      2)The Copper Tube is fully shaped and then installed into the shell thus free from Products processing defects.   

      3)There is no block on water loop and the water flow is smooth,thus keep it avoid dirty.
      4)The water pipe is on the lowest position ,and easy for drainage in cold season,avoid freeze. 

      Usage:
      It can be widely used in drinking water of the cooling/heating,dairy beverage heating/cooling, chemistry, chemicalengineering, bio-food, medicine and other special industriescooling/heating heat exchanger; because of its unique twotier inner tube structure, and to prevent leakage in the heatexchanger. Used for participating in the two kinds of heatexchange media, anti-channeling does not occur, resulting in 
      leakage after the media flow in the double-decker sanchwich of
      Copper tube and efficient, cross-contamination does not occur.Improved heat exchange of security and reliability.


      Structure
      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump

       

      Specification:
      Model
      Heating capacity
      Cooling capacity
      Water flow
      Heat exchanger tube
      GBHE-01
      5.0KW 
      3.8KW 
      1.0 m3/h
       19.05 Copper tube
       
      GBHE-02
      8.5KW 
      6.7KW
      1.6 m3/h
      19.05 Copper tube
      GBHE-03 
      10.5KW
      8.6KW
      1.8 m3/h
      19.05 Copper tube
      GBHE-04 
      12.5KW 
      9.2KW 
      1.8 m3/h
      19.05 Copper tube
      GBHE-05 
      23.5KW 
      17.6KW 
      3 m3/h
      19.05*2 Copper tube
      GBHE-06
      26.5KW
      20.5KW 
      3.2 m3/h
      19.05*2 Copper tube
      GBLE-07
      47KW 
      37KW 
      6.5 m3/h
      24.5*2 Copper tube
      GBLE-08
      54.5KW
      43.5KW
      7 m3/h
      24.5*2 Copper tube
               

      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump
      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump

      Packing&Shipping:
      Wooden case packing fixation.
      The stocking period is 15 days.
      If you need customized packaging, please contact us.



      Gbhe-01 Accumulator Excluded Heat Exchanger Use for Heat Pump


       

      FAQ:

       

      About price:
      The price is negotiable.It can be changed according to your quantity or package.Please let us know the quantity you require when
      you make an inquiry.

       

      About the sample:
      The sample is free of charge, but the air freight is to be paid by you, otherwise you need to pay in advance.

       

      About MOQ:
      The moq is 100 pieces;We have some products in stock.The moq is 20 pieces.

       

      About warranty:
      we have confidence in our products and our packing is good, so normally you will receive your order in good condition.Any quality
      problem will be dealt with immediately.


       

      Send your message to this supplier

      *From:
      *To:
      *Message:

      Enter between 20 to 4,000 characters.

      This is not what you are looking for? Post a Sourcing Request Now